Motor Electrical
NORMALElectrical behaviour is consistent with normal pump operation.
33.5 Hz · 1.4 A · 84.1% load
MEASURED
Pilot 1 · CSV Fountain
Current AI assessment
Pump is operating normally.
What should I do?
Continue normal operation. No inspection is currently required.
Electrical behaviour is consistent with normal pump operation.
33.5 Hz · 1.4 A · 84.1% load
MEASURED
No active drive fault detected.
DC bus 304.6 V · Output 214 V
MEASURED
Measured water delivery is consistent with current operation.
200.89 LPM · MEASURED
Actual 33.5 Hz ↔ Recommended 33.5 Hz
HOLD · 90% confidence
MEASURED + AI RECOMMENDED
Monitored Subsystem Health
Available electrical measurements are consistent with the reported operating state.
Recommended action
Continue monitoring electrical consistency across operating periods.
Monitoring scope: Electrical operating assessment; bearings, winding temperature and insulation are not diagnosed
Provenance: MEASURED
No active drive fault or inconsistent electrical state is present in the latest sample.
Recommended action
Continue monitoring VFD fault and output consistency.
Monitoring scope: Latest INVT VFD telemetry; no internal physical component diagnosis
Provenance: MEASURED
Measured flow is consistent with the latest reported operating state.
Recommended action
Continue comparing measured flow under comparable frequency and load.
Monitoring scope: Hydraulic operating assessment; does not diagnose seal or impeller condition
Provenance: MEASURED
Pump-level performance is assessed indirectly from the available operating relationship.
Recommended action
Review comparable operating periods when the frequency-load-flow relationship changes persistently.
Monitoring scope: Indirect pump operating assessment; not an internal physical component diagnosis
Provenance: INDIRECT
The latest sample and available continuity evidence are current.
Recommended action
Continue monitoring sample freshness and continuity.
Monitoring scope: Communications availability only; history unavailability does not invalidate current telemetry assessments
Provenance: TELEMETRY
Monitoring limits
AI-Kit can detect changes in monitored operating behaviour, but current instrumentation cannot always identify the exact physical component responsible. These coverage labels are not faults.
No dedicated vibration or bearing-temperature measurement is available.
Electrical operating indicators do not directly measure winding temperature or insulation condition.
No leakage, pressure, or seal-specific sensor is available.
Hydraulic behavior may indicate a pump-side issue, but current instrumentation cannot identify an impeller condition.
AI-assisted optimization context; actual operation remains visible beside the recommendation.
Telemetry history: live.